Penn-Union Master Catalog

COPPER COMPRESSION SPLICES

Type BCU-FL Flared Crimp Splice - Standard Barrel • Suitable for use with Class B, C, I, K, H, G, M and DLO conductors • Manufactured from high conductivity seamless copper tubing • Tin plated to inhibit corrosion • Flared barrel entry provides easy cable insertion for fine stranded cables and minimizes strain during flexing and movement • Positive cable stops to ensure proper insertion of conductors to full depth • Color coded barrels are marked with die index numbers • Connectors are suitable for voltages up to 35 KV if taped according to accepted practices, 5 KV is the maximum voltage level in all bare splice applications • Connectors are UL listed and CSA certified with Penn-Union, Burndy, T&B, Huskie, Greenlee and Versa-Crimp ® style tooling

FIGURE DIMENSIONS (IN.)

INSTALLATION TOOLING

WIRE STRIP LENGTH

COPPER CONDUCTOR SIZE

OVERALL LENGTH “L”

COLOR CODE

BURNDY DIE INDEX NO.

INSERTION LENGTH “B”

PENN-UNION DIE CATALOG NO.

CATALOG NUMBER

PENN-UNION DIELESS MECHANICAL TOOL

105/24 4 WELD; 3 AWG 150/24 2 WELD; 1 AWG

BCU-3-FL

.88

1.84

White

9

T-9

1”

BCU-1-FL

.88

1.84

Green

11

T-11

1”

225/24 1 WELD; 1/0 AWG 275/24 1/0 WELD; 2/0 AWG 325/24 2/0 WELD; 3/0 AWG 450/24 3/0 WELD; 4/0 AWG 550/24 4/0 WELD; 300 kcmil 650/24; 350 kcmil 775/24; 400 kcmil 925/24; 500 kcmil 1100/24; 600 kcmil 1325/24; 650 kcmil 1600/24; 750 kcmil 1925/24; 1000 kcmil 2750/24; 1500 kcmil

.88

1.84

Pink

12

T-12

1”

BCU-1/0-FL

TDM-250XF

BCU-2/0-FL

.94

1.96

Black

13

T-13 1-1/16”

BCU-3/0-FL

1.00

2.09

Orange

14

T-14

1-1/8”

BCU-4/0-FL

1.00

2.09

Purple

15

T-15

1-1/8”

1.06

2.21

White

17

T-17 1-3/16”

BCU-030-FL

BCU-035-FL BCU-040-FL BCU-050-FL BCU-060-FL BCU-065-FL BCU-075-FL BCU-100-FL BCU-150-FL

1.13 1.19 1.38 1.38 1.38 1.63 1.88 2.00

2.34 2.46 2.84 2.84 2.84 3.34 3.84 4.09

Red Blue

18 19 20 22

T-18

1-1/4”

T-19 1-5/16”

Brown Green

T-20 T-22

1-1/2” 1-1/2”

Pink

300

T-300 1-1/2”

Black White Green

24 27 31

T-24

1-3/4”

T-27P

2”

T-31P 2-1/8”

For additional wire size recommendations please refer to page 81 • Connectors from 8 AWG - 2000 kcmil are UL listed per UL486A-B and CSA certified per C22.2 No.65 for POWER applications • Connectors from 8 AWG - 500 kcmil are UL listed for grounding, bonding and direct burial applications per UL467 • Connectors from 8 AWG - 250 kcmil are CSA certified for grounding, bonding and direct burial applications per C22.2 No.41

50

Powered by