Type BBCU-FL Flared Crimp Splice - Long Barrel • Suitable for use with Class B, C, I, K, H, G, M and DLO conductors • Manufactured from high conductivity seamless copper tubing • Tin plated to inhibit corrosion • Flared barrel entry provides easy cable insertion for fine stranded cables and minimizes strain during flexing and movement • Positive cable stops to ensure proper insertion of conductors to full depth • Long barrel provides high pull out force and added secureness for improved mechanical and electrical properties • Color coded barrels are marked with die index numbers • Connectors are suitable for voltages up to 35 KV if taped according to accepted practices, 5 KV is the maximum voltage level in all bare splice applications • Connectors are UL listed and CSA certified with Penn-Union, Burndy, T&B, Huskie, Greenlee and Versa-Crimp ® style tooling
FIGURE DIMENSIONS (IN.)
INSTALLATION TOOLING
INSERTION LENGTH “B”
OVERALL LENGTH “L”
COLOR CODE
PENN-UNION DIELESS MECHANICAL TOOLS
COPPER CONDUCTOR SIZE
BURNDY DIE INDEX NO.
PENN-UNION DIE CATALOG NO.
WIRE STRIP LENGTH
CATALOG NUMBER
105/24 4 WELD; 3 AWG 150/24 2 WELD; 1 AWG
BBCU-3-FL
1.13
2.38
White
9
T-9
1-1/4”
BBCU-1-FL
1.38
2.84
Green
11
T-11
1-1/2”
225/24 1 WELD; 1/0 AWG 275/24 1/0 WELD; 2/0 AWG 325/24 2/0 WELD; 3/0 AWG 450/24 3/0 WELD; 4/0 AWG 550/24 4/0 WELD; 300 kcmil 650/24; 350 kcmil 775/24; 400 kcmil 925/24; 500 kcmil 1100/24; 600 kcmil 1325/24; 650 kcmil 1600/24; 750 kcmil 1925/24; 1000 kcmil 2750/24; 1500 kcmil
BBCU-1/0-FL
1.38
2.84
Pink
12
T-12
1-1/2”
TDM-250XF
BBCU-2/0-FL
1.50
3.09
Black
13
T-13
1-5/8”
BBCU-3/0-FL
1.50
3.09
Orange
14
T-14
1-5/8”
BBCU-4/0-FL
1.63
3.34
Purple
15
T-15
1-3/4”
BBCU-030-FL
2.00
4.09
White
17
T-17
2-1/8”
BBCU-035-FL BBCU-040-FL BBCU-050-FL BBCU-060-FL BBCU-065-FL BBCU-075-FL BBCU-100-FL BBCU-150-FL
2.00 2.13 2.25 2.69 2.75 2.88 3.00 3.19
4.09 4.34 4.59 5.46 5.63 5.84 6.09 6.46
Red Blue
18 19 20 22
T-18 T-19 T-20
2-1/8” 2-1/4” 2-3/8”
Brown Green
T-22 2-13/16” T-300 2-7/8”
Pink
300
Black White Green
24 27 31
T-24
3”
T-27P 3-1/8” T-31P 3-5/16"
For additional wire size recommendations please refer to page 81 • Connectors from 8 AWG - 2000 kcmil are UL listed per UL486A-B and CSA certified per C22.2 No.65 for POWER applications • Connectors from 8 AWG - 500 kcmil are UL listed for grounding, bonding and direct burial applications per UL467 • Connectors from 8 AWG - 250 kcmil are CSA certified for grounding, bonding and direct burial applications per C22.2 No.41
51
Powered by FlippingBook